What the check covers
Every check below runs on each job. Methods not listed are not guessed at.
Checks
Code does the arithmetic and makes every call. AI only reads documents into fields, and each value it reads must be found on the page it cites before it is used.
- Results and averages, recomputedPrinted run averages against the runs. O2-corrected values against the measured ones. Percent reduction against inlet and outlet. Percent load against horsepower.
- Bias-corrected run resultsEach instrumental run worked out with Method 7E Eq. 7E-5b and compared with the printed value, allowing only for the rounding of the printed readings.
- Calibration error, system bias and driftAgainst the Method 7E limits, for Methods 3A, 7E and 10.
- Gas cylindersCertificate values against the report's gas table and the ERT file. Cylinders that expired before the test or were certified after it. A calibration that uses a cylinder not on the list.
- Run times and datesRuns in order, none starting before the one before it. Results tied to runs that exist. Runs left out with no reason given.
- UnitsA unit that doesn't fit the gas, such as O2 in ppm or NOx in percent. Units and compound names ERT does not accept.
- The report against itselfThe same value printed twice, differently. References to tables or appendices the report doesn't have.
- Text carried over from another jobA turbine named in an engine report. A cover date that isn't the test date. A unit name that isn't this job's.
- ERT completenessFields ERT requires that are empty. One unit spelled several ways. A source classification code that likely doesn't match the unit.
Where a rule asks for something the report doesn't show, such as the test load or the basis of a percent reduction, the check asks a question instead of passing or failing it.
Methods and rules built today
Report drafts from field data
- South Coast AQMD Rule 1146 and 1146.1 boilers, steam generators and process heaters: SCAQMD Method 100.1 (NOx, CO, O2) from the DAS export and calculation workbook.
- Flare tests under South Coast AQMD Rule 1118.1: a draft from your calculation workbooks, laboratory reports and your own Word sections.
- Mojave Desert AQMD Rule 1157 boilers: test protocol and notice.
ERT files and the pre-filing check, from a finished report
- EPA Methods 3A (O2, CO2), 6C, 7E, 10 and 25A, with cylinders, calibrations and pre- and post-run system checks.
- Results reported under Method 19, Method 18, Method 320 and ASTM D6348.
- Tested on public engine and turbine filings from EPA WebFIRE.
In progress
- UK periodic monitoring reports (Environment Agency and MCERTS guidance) in progress
A method, district or template we haven't built is not guessed at. We say so and stop.